This is an odor-free water - based, non - toxic, non - acid concrete cleaner and sealer which may be applied to new or old concrete. Its powerful detergent combination flushes out oil and dirt from concrete, for a clean look and good adhesion of anything else. It contains no solvents whatsoever. Its V.O.C. [Volatile Organic Content] is zero. New Concrete Applications New concrete will do most of its curing in the first few weeks, as the capillary network and bleed holes show their development. The strength of concrete slowly continues to increase over the next few years, as a microscopic crystalline network develops. For this reason, we recommend that the application of the sealer to new concrete be repeated a year or two later in cases where absolutely no porosity in concrete may be tolerated. As concrete cures it will develop new porosity , regardless of how well sealed it was initially. Knowing this, the contractor can properly inform his customer and avoid call - backs and/or future headaches. Old Concrete Applications Old concrete is chemically stable and its porosity fully developed. The typical age [at which chemical stability is attained, and chemically-bonded coatings will stick] depends on average annual temperature. All chemical reactions go faster in warmer weather, the rate doubling with every [roughly] eighteen Fahrenheit degree increase. Attaining this minimum degree of chemical stability typically takes two years in the latitude of San Diego, CA, or Miami, FL, or five years at the latitude of the San Francisco Bay in CA or the Chesapeake Bay in Virginia. In colder climates such as Seattle, WA or Maine this can take fifteen to twenty years. Such concrete does not develop further porosity with age, and is chemically stable. One series of treatments can completely seal the concrete, and the seal is permanent . Then a coating can stick and stay stuck. Then a coating can stick and stay stuck. This is due to our 100% Acrylic-free formulation, based instead on the mineral chemistry of concrete itself. It will even stop salt - water deterioration of concrete pilings if the sealing is thoroughly done, and the concrete steam-cured [72 hrs@180deg. F.] before installation. Dusting and efflorescence of old concrete surfaces can be stopped entirely . However, old or extremely porous concrete may take more than two or three applications until no further penetration is observed. Extremely porous, crumbly concrete should have an epoxy sealer treatment instead. Most coatings can be made to stick to concrete, with proper surface preparation. Then, they stay stuck. Application Old concrete which may have absorbed food spills, grease or oil, antifreeze, brake fluid or hydraulic fluid will not stick if not chemically cleaned. Abrasive-blasting does not remove soaked-in contamination, and that such oily residue still dissolve in and come to the surface of the first coating to be applied. This is why a precleaner is necessary. The powerful detergent combination in Smith's Permanent Concrete Sealer flushes oils or dirt from concrete porosity. This chemical surface treatment will also seal the microscopic porosity of the concrete. It also chemically activates the concrete and silica sand grains in the surface, so that a good chemical bond may be obtained with subsequent coatings. To use, mix two gallons of concentrate with three gallons of water to make five gallons of Smith’s Permanent Concrete Sealer ™, ready to use. Apply Smith’s Permanent Concrete Sealer at a coverage of about 50-200 square feet per gallon, depending on concrete porosity. Apply as much as immediately soaks in . The average concrete slab takes about 100 square feet per gallon. One should apply as much as will soak into the concrete. It is then covered with a plastic sheet to prevent water evaporation. Do not let any of this sealer dry hard on the concrete surface; it will be difficult to remove and will interfere with adhesion of subsequent coatings . The seal develops by a chemical reaction with the concrete, and this is a fairly slow reaction. Keep covered for five hours at 77F/25C [longer in colder weather]. Then the plastic sheet cover is removed and the concrete is rinsed with tap water while being scrubbed with a stiff bristle brush or push-broom.
At this point the
concrete surface should show water standing, not soaking in. That
proves
it has been sealed against liquid water and oil absorption. It can
still
pass water vapor, however. This seal is based on a mineral kind of
chemistry
similar to the concrete itself. Acrylic-emulsion-type sealers and
organic
silane sealers biodegrade and weather away, and need to be repeated.
Our
technology is 100% Acrylic-free™, and
on fully cured concrete,
this seal is permanent
. This treatment is sufficient to
seal concrete against efflorescence. The cause of efflorescence, the
white
stains commonly appearing on concrete, is dissolved minerals left
behind
when ground-water evaporates from a brick or concrete surface. When the
concrete surface is treated in this manner, liquid water cannot reach
the surface. This sealer passes water vapor only, thus the evaporation
of the water takes place below the surface The dissolved minerals
[usually
calcium carbonate, limestone] are deposited within the concrete,
below
the surface where they cannot be seen and actually contribute to
further
sealing and densification of the bulk porosity of the concrete.
Some stucco or sprayed - concrete surfaces exhibit higher porosity, and after the usual procedure some absorption of water may still be apparent. Concrete blocks are an extreme example. This sealer should not be used on such surfaces. The subject of sealing the very large pores of concrete blocks is covered in a separate application note. Below - grade concrete basement walls may be sealed from the inside, providing the work is done during the dry season, when ground water is not flowing in. Flowing water would prevent sealer penetration. Actual cracks in concrete may be sealed with rubber sealants. If the concrete slabs have absolutely no capability for movement, epoxy or cement grouts may be used to seal cracks. White or colored stains or powders may develop on the surface in the days or weeks after Sealer application. The particular history of the concrete is responsible, and this cannot be predicted in advance. Application on a small test area is recommended, where the concrete has an unknown history and final appearance is of concern.
Copyright
© 2005 Steve Smith all rights reserved
|